Pulsers mounted on flowmeter rotors enable (provided that suitable flowmeters are used) the measurement of the current value of flow, as well as drawing up a balance ratio.

name
General descrption
parameters
  • SPI-73
    SPI-73 are the flow meters designed to work in tandem with the pulse flow transducers with coefficients ranging from 0,01 to 9999,99 pulses per litre. Wide range of total flow (up to 15...
    more
    Inputs pulse galvanically isolated with contacts oscillation damping, max. frequency from 10 kHz; reset of totalizer counter: edge or level triggered, galvanically isolated
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
    Protection class IP 65 (front), available additional frame IP 65 for panel cut-out sealing; IP 20 (case and connection clips)
  • SPI-94
    SPI-94 are the flow meters designed to work in tandem with the pulse flow transducers with coefficients ranging from 0,01 to 9999,99 pulses per litre, equipped with electronic (open...
    more
    Inputs pulse galvanically isolated with contacts oscillation damping, max. frequency from 10 kHz; reset of totalizer counter: edge or level triggered, galvanically isolated
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
    Protection class IP 65 (front), available additional frame IP 65 for panel cut-out sealing; IP 20 (case and connection clips)
  • SPP-94
    SPP-94 are the flow meters designed to work in tandem with the pulse flow transducers with current input of 0-20 mA or 4-20 mA. Wide range of total flow (up to 16 significant digits)...
    more
    Inputs measurement: current 0-20 mA or 4-20 mA, overload-protected,sinking current limited to about 40 mA; programmable: binary 24V DC, not separated
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
    Protection class IP 65 (front), available additional frame IP 65 for panel cut-out sealing; IP 20 (case and connection clips)
  • SPI-N118
    SPI-N118 are the flow meters in tight, wall mounted case (IP 67), designed to work in tandem with the pulse flow transducers with coefficients ranging from 0,01 to 9999,99 pulses per...
    more
    Inputs pulse, fully isolated; zeroing of batcher counter, zeroing of total counter and counting blockade: active edge or level; pulse input counting input with debouncing filter and pulse width control, max. input frequency 10.0 kHz
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC, all separated
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 5 VA; for 19V ÷ 50V DC power supply: max. 5 W
    Protection class IP 67
  • SPI-638
    The SPI-638 flow counters encased in a tight, wall-mounted housing (IP 67) with 6-digit, large LED display are designed to work together with flow transducers equipped with contact or...
    more
    Inputs pulse, fully isolated; zeroing of batcher counter, zeroing of total counter and counting blockade: active edge or level; pulse input counting input with debouncing filter and pulse width control, max. input frequency 10.0 kHz
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC, all separated
    Power consumption for 19V ÷ 50V DC: max. 8,7 W; for 16V ÷ 35V AC max. 13 VA; for 85 ÷ 260V AC/DC max. 29 VA
    Protection class IP 67
  • SPP-N118
    SPP-N118 are the flow meters in tight, wall mounted case (IP 67), designed to work in tandem with the pulse flow transducers with current input of 0-20 mA or 4-20 mA. Wide range of total...
    more
    Inputs measurement: current 0-20 mA or 4-20 mA, overload-protected,sinking current limited to about 40 mA; programmable: binary 24V DC, not separated
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC, all separated
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 5 VA; for 19V ÷ 50V DC power supply: max. 5 W
    Protection class IP 67
  • SPP-638
    The SPP-638 flow counters encased in a tight, wall-mounted housing (IP 67) with 6-digit, large LED display are designed to work together with flow transducers equipped with analogue...
    more
    Inputs current: 0 ÷ 20 mA or 4 ÷ 20 mA, overload-protected, sinking current limited to ca. 40 mA, input resist.: < 65 Ω (typ. 50 Ω) programmable: binary 24V DC, not separated
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC, all separated
    Power consumption for 19V ÷ 50V DC: max. 8,7 W; for 16V ÷ 35V AC max. 13 VA; for 85 ÷ 260V AC/DC max. 29 VA
    Protection class IP 67
  • MultiCon CMC-N16
    As a result of extending the range of functional applications of the MultiCon product line, the CMC-N16 wall mounted model has been designed. The new IP 65 enclosure allows using the...
    more
    Inputs 2 or 4 universal, isolated: 0/4 ÷ 20 mA (also totalizer mode); 0/1 ÷ 5V, 0/2 ÷ 10V; thermocouples: J, K, S, T, N, R, B, E (PN-EN), L (GOST); -10 ÷ 25 mV, -10 ÷ 100 mV, 0 ÷ 600 mV; RTD (2/3 wire): Pt100, Pt500, Pt1000 (PN-EN), Pt'50, Pt'100, Pt'500 (GOST), Ni100, Ni500, Ni1000 (PN-EN), Cu50, Cu100 (PN-83M-53852), Cu'50, Cu'100 (PN-83M-53852); resistance 0 ÷ 300 Ω, resistance 0 ÷ 3 kΩ; 2 universal pulse counter / ratemeter, (max. freq. 5 kHz); 5 digital inputs 24V DC (1 input available in standard, integrated with PS32 or PS42 power supply module)
    Power consumption typical 15 VA, max. 20 VA
    Power supply 19-50V DC, 16-35V AC or 85-260V AC/DC
    Outputs 2 or 4: analogue 4 ÷ 20 mA (passive, isolated, resolution 14 bit); SPST relay 1A/250V; SSR passive (OC with PWM); mixed outputs (2 x REL / 2 x 4 ÷ 20 mA, 2 x REL / 2 x SSR passive, 2 x 4 ÷ 20 mA / 2 x SSR); sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)
  • MultiCon CMC-99
    The MultiCon CMC-99 is a powerful and versatile compact-multichannel-controller with a capability to record data, if the recording function is requested and activated. Thanks to that it...
    more
    Inputs 9 universal inputs max.; 48 analogue inputs (0/4-20 mA or 0/1-5V or 0/2-10V) max.; 48 digital inputs max.; 24 thermocouple inputs max.; 12 RTD inputs max.; 12 counter/ flowmeter/ ratemeter inputs max.; 1 digital input 24V DC (available in standard, integrated with PS3 or PS4 power supply module)
    Power consumption typical 15 VA; max. 20 VA
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Outputs 8 analog (4-20 mA) max.; 16 relay (1A/250V) max.; 4 relay 5A/250V max. or 48 SSR outputs, sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)
  • MultiCon CMC-141
    The Multicon CMC are powerful and versatile compact-multichannel-controllers with a capability to record data, if the recording function is requested and activated. MultiCon CMC‑141 is...
    more
    Inputs up to 15 universal inputs; 72 analogue inputs (0/4-20 mA or 0/1-5V or 0/2-10V) max.; 72 digital inputs max.; 36 thermocouple inputs max.; 18 RTD inputs max.; 12 counter/ flowmeter/ ratemeter inputs max.; 1 digital input 24V DC (available in standard, integrated with  PS3 or PS4 power supply module)
    Power consumption typical 25 VA; max. 35 VA
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Outputs 24 analog (4-20 mA) or 36 relay (1A/250V) / 72 SSR outputs or 18 relay 5A/250V max., sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)