Website uses cookies in ways described in the cookie policy (read). While using this website without changing browser settings, you agree to use cookies, and know that some data will be stored on your browsing device. Mind that that you can always change these settings. Close
unia europejska

simex - pomiar i sterowanie

Universal

SIMEX offers high quality digital meters with universal input, designed for the measurement systems, control and regulator of different technological processes. Type of controlled values depending on the connected sensor and actuator changing a given physical value. With expanded utility functions they can be used for most tasks to stabilize the temperature, humidity and other physical quantities, in cooperation with analog signals.

name
General descrption
parameters
  • SWE-94-U
    The SWE-94-U meter is equipped with one universal input: 0-20 mA, 0-10V, 0-150 mV, RTD (Pt 100/500/1000) or thermocouple (K, S, J, T, N, R, B, E). Temperature of cold ends is compensated...
    more
    Inputs universal (programmable): current; voltage; milivoltage; thermoresistance or thermocouple type K, S, J, T, N, R, B, E
    Power consumption for 110V AC and 230V AC: max. 1,5 VA; for 24V DC: max. 1 W
    Display LED, red, 4 x 20 mm high, brightness adjustable in 8 steps
    Measurement range current: 0-20 mA or 4-20 mA, voltage 0-5 V, 1-5V, 0-10V or 2-10V, milivoltage 0-60 mV, 0-75 mV, 0-100 mV or 0-150 mV; thermoresistance: Pt100, Pt500, Pt1000, measuring range -100°C ÷ 600°C; thermocouple K: -200°C ÷ +1370°C; S: -50°C ÷ +1768°C; J: -210°C ÷ +1200°C; T: -200°C ÷ +400°C; N: -200°C ÷ +1300°C; R: -50°C ÷ +1768°C; B: +250°C ÷ +1820°C; E: -200°C ÷ +1000°C
  • SUR-94
    Meter with large, readable display, with universal input (0/4-20mA, 0-10V, 0-150 mV, Pt 100/500/1000 or TC type K, S, J, T, N, R, B, E), with 0, 2 or 4 relay (or OC type) outputs and 1...
    more
    Inputs universal (programmable): current; voltage; milivoltage; thermoresistance or thermocouple type K, S, J, T, N, R, B, E
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
    Outputs 0, 2 or 4 relays 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
  • SUR-457
    Meter with large, readable 57-mm LED display (ultra bright red, green and blue as well as multicolour LED's), universal input (0/4-20mA, 0-10V, 0-150 mV, Pt 100/500/1000 or TC type...
    more
    Inputs universal (programmable): current; voltage; milivoltage; thermoresistance or thermocouple type K, S, J, T, N, R, B, E
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption for 19V ÷ 50V DC: max. 13,5 W; for 16V ÷ 35V AC: max. 19,5 VA; for 85 ÷ 260V AC/DC: max. 21 VA
    Outputs 2 or 4 relay 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
  • MultiCon CMC-N16
    As a result of extending the range of functional applications of the MultiCon product line, the CMC-N16 wall mounted model has been designed. The new IP 65 enclosure allows using the...
    more
    Inputs 2 or 4 universal, isolated: 0/4 ÷ 20 mA (also totalizer mode); 0/1 ÷ 5V, 0/2 ÷ 10V; thermocouples: J, K, S, T, N, R, B, E (PN-EN), L (GOST); -10 ÷ 25 mV, -10 ÷ 100 mV, 0 ÷ 600 mV; RTD (2/3 wire): Pt100, Pt500, Pt1000 (PN-EN), Pt'50, Pt'100, Pt'500 (GOST), Ni100, Ni500, Ni1000 (PN-EN), Cu50, Cu100 (PN-83M-53852), Cu'50, Cu'100 (PN-83M-53852); resistance 0 ÷ 300 Ω, resistance 0 ÷ 3 kΩ; 2 universal pulse counter / ratemeter, (max. freq. 5 kHz); 5 digital inputs 24V DC (1 input available in standard, integrated with PS32 or PS42 power supply module)
    Power supply 19-50V DC, 16-35V AC or 85-260V AC/DC
    Power consumption typical 15 VA, max. 20 VA
    Outputs 2 or 4: analogue 4 ÷ 20 mA (passive, isolated, resolution 14 bit); SPST relay 1A/250V; SSR passive (OC with PWM); mixed outputs (2 x REL / 2 x 4 ÷ 20 mA, 2 x REL / 2 x SSR passive, 2 x 4 ÷ 20 mA / 2 x SSR); sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)
  • MultiCon CMC-99
    The MultiCon CMC-99 is a powerful and versatile compact-multichannel-controller with a capability to record data, if the recording function is requested and activated. Thanks to that it...
    more
    Inputs 9 universal inputs max.; 48 analogue inputs (0/4-20 mA or 0/1-5V or 0/2-10V) max.; 48 digital inputs max.; 24 thermocouple inputs max.; 12 RTD inputs max.; 12 counter/ flowmeter/ ratemeter inputs max.; 1 digital input 24V DC (available in standard, integrated with PS3 or PS4 power supply module)
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption typical 15 VA; max. 20 VA
    Outputs 8 analog (4-20 mA) max.; 16 relay (1A/250V) max.; 4 relay 5A/250V max. or 48 SSR outputs, sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)
  • MultiCon CMC-141
    The Multicon CMC are powerful and versatile compact-multichannel-controllers with a capability to record data, if the recording function is requested and activated. MultiCon CMC‑141 is...
    more
    Inputs up to 15 universal inputs; 72 analogue inputs (0/4-20 mA or 0/1-5V or 0/2-10V) max.; 72 digital inputs max.; 36 thermocouple inputs max.; 18 RTD inputs max.; 12 counter/ flowmeter/ ratemeter inputs max.; 1 digital input 24V DC (available in standard, integrated with  PS3 or PS4 power supply module)
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption typical 25 VA; max. 35 VA
    Outputs 24 analog (4-20 mA) or 36 relay (1A/250V) / 72 SSR outputs or 18 relay 5A/250V max., sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)

SIMEX Sp. z o.o.

ul. Wielopole 11

80-556 Gdańsk

Poland

tel. (+48 58) 76-20-777

fax (+48 58) 76-20-770

inquiry@simex.pl