Website uses cookies in ways described in the cookie policy (read). While using this website without changing browser settings, you agree to use cookies, and know that some data will be stored on your browsing device. Mind that that you can always change these settings. Close
unia europejska

simex - pomiar i sterowanie

Current / voltage

Digital industrial meters constitute the largest family of automation equipment, ranging from the simplest meters that are designed only to display basic parameters such as working status or physical quantities (level, pressure etc.), to more complex control units having a number of relay outputs. The appliances of this group can be equipped with inputs for current, voltage or millivolts. There are a variety of designs: enclosures in different sizes and with displays of various sizes, or even wall-mounted enclosures, enabling the free selection of the desired type of appliance while at the same time maintaining complete functional compatibility. The additional option of current output, installed in a number of appliances, enables easy retransmission of the measured parameter to systems equipped with PLC controllers, or, for example, to other meters.

name
General descrption
parameters
  • SWE-73-A
    Simple digital panel indicator, equipped with measurement input: current input (0-20/4-20 mA) or voltage input (0-5/1-5/0-10/2-10 V).
    more
    Power supply 230 V AC ± 10%; 110 V AC ± 10%; 24 V DC (non separated from measurement input)
    Inputs current 0-20 mA or 4-20 mA, user programmable, overload-protected, input current limited to about 50 mA; voltage 0-5 V, 1-5V, 0-10V or 2-10V, user programmable
    Power consumption for 110V AC and 230V AC: max. 1,5 VA; for 24V DC: max. 1 W
    Case material NORYL UL94 V-0
  • SWE-73-L
    Simple and low cost digital indicator with a single 4-20 mA current input, which powers this device at the same time. Measurement input is equipped with safety circuits, saving internal...
    more
    Power supply from measurement line, min. current 3.5 mA, max. voltage drop 7V
    Inputs current 4-20 mA, overload-protected, input current limited to about 50 mA
    Case material NORYL UL94 V-0
    Display LED, red, 4 x 13 mm high
  • SWE-N55L
    Simple and low cost digital indicator in a small wall case, with a single 4-20 mA current input, which powers this device at the same time. Measurement input is equipped with safety...
    more
    Power supply from measurement line, min. current 3.5 mA, max. voltage drop 7V
    Inputs current 4-20 mA, overload-protected, input current limited to about 50 mA
    Outputs 1 x bistable relay 30V/500 mA, min. switching delay: about 4 sec. (option)
    Case material polycarbonate
  • SRP-73
    Meter in small case, with current-voltage or mV input, with 1 or 2 relay (or OC type) outputs. The version without relay outputs is also available.
    more
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Inputs current 0-20 mA or 4-20 mA, programmable, input resistance < 65 Ohm (typ. 55 Ohm), overload-protected, input current limited to 40 mA; voltage 0-5 V, 1-5V, 0-10V or 2-10V, programmable, input resistance > 50 kOhm; milivoltage 0-60 mV, 0-75 mV, 0-100 mV, 0-150 mV; programmable; input resistance > 100 kOhm
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
    Outputs 0, 1 or 2 relays 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
  • SRP-77
    Meter with 2 displays, with current-voltage input, with 1 or 2 relay (or OC type) outputs. The version without relay outputs is also available.
    more
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Inputs current 0-20 mA or 4-20 mA, programmable, input resistance < 65 Ohm (typ. 55 Ohm), overload-protected, input current limited to 40 mA; voltage 0-5 V, 1-5V, 0-10V or 2-10V, programmable, input resistance > 50 kOhm
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
    Outputs 0, 1 or 2 relays 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
  • SRP-94 / SRP-946
    The SRP-94(6) meter is designed for measuring of typical current or voltage signals. The readouts are presented on well-readable display with standard range of four digits or five/six...
    more
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Inputs current 0-20 mA or 4-20 mA, programmable, input resistance < 65 Ohm (typ. 55 Ohm), overload-protected, input current limited to 40 mA; voltage 0-5 V, 1-5V, 0-10V or 2-10V, programmable, input resistance > 50 kOhm; milivoltage 0-60 mV, 0-75 mV, 0-100 mV, 0-150 mV; programmable; input resistance > 100 kOhm
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
    Outputs 0, 2 or 4 relays 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
  • SRP-N118 / SRP-N1186
    Meter in tight (IP 67), wall mounting case, with current-voltage input, 2 relay (or OC type) outputs and 1 analogue output, according to the customer selection: active current output,...
    more
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC, all separated
    Inputs current 0-20 mA or 4-20 mA, programmable, input resistance < 65 Ohm (typ. 55 Ohm), overload-protected, input current limited to 40 mA; voltage 0-5 V, 1-5V, 0-10V or 2-10V, programmable, input resistance > 50 kOhm
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 5 VA; for 19V ÷ 50V DC power supply: max. 5 W
    Outputs 0 or 2 relays 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized
  • SRL-49
    Meter with colour bargraf, with current-voltage input, 2 or 4 relay (or OC type) outputs and 1 analogue output, according to the customer selection: active current output, passive...
    more
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Inputs current 0-20 mA or 4-20 mA, programmable, input resistance < 65 Ohm (typ. 55 Ohm), overload-protected, input current limited to 40 mA; voltage 0-5 V, 1-5V, 0-10V or 2-10V, programmable, input resistance > 50 kOhm
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
    Outputs 0, 2 or 4 relays 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
  • SRP-147
    Meter with large display (digits 38 mm), with current-voltage or mV input, with 2 or 4 relay (or OC type) outputs and 1 analogue output, according to the customer selection: active...
    more
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Inputs current 0-20 mA or 4-20 mA, programmable, input resistance < 65 Ohm (typ. 55 Ohm), overload-protected, input current limited to 40 mA; voltage 0-5 V, 1-5V, 0-10V or 2-10V, programmable, input resistance > 50 kOhm
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
    Outputs 0, 2 or 4 relays 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
  • SWP-99X
    The SWP-99X indicator is intended for measuring and presentation of current values from 8 measuring channels. Each channel can be individually designated (described) with any measuring...
    more
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Inputs 2, 4 or 8 inputs: 0/4-20 mA (input resistance 100 Ω) or 0/1-5 V, 0/2-10 V (input resistance 60 kΩ), common earthing
    Power consumption typical 7 VA; max. 12 VA
    Outputs 2 electronic relays, NO type (ER1, ER2) with max. load 24V AC (35V DC) / 200 mA, overload protection
  • MultiCon CMC-N16
    As a result of extending the range of functional applications of the MultiCon product line, the CMC-N16 wall mounted model has been designed. The new IP 65 enclosure allows using the...
    more
    Power supply 19-50V DC, 16-35V AC or 85-260V AC/DC
    Inputs 2 or 4 universal, isolated: 0/4 ÷ 20 mA (also totalizer mode); 0/1 ÷ 5V, 0/2 ÷ 10V; thermocouples: J, K, S, T, N, R, B, E (PN-EN), L (GOST); -10 ÷ 25 mV, -10 ÷ 100 mV, 0 ÷ 600 mV; RTD (2/3 wire): Pt100, Pt500, Pt1000 (PN-EN), Pt'50, Pt'100, Pt'500 (GOST), Ni100, Ni500, Ni1000 (PN-EN), Cu50, Cu100 (PN-83M-53852), Cu'50, Cu'100 (PN-83M-53852); resistance 0 ÷ 300 Ω, resistance 0 ÷ 3 kΩ; 2 universal pulse counter / ratemeter, (max. freq. 5 kHz); 5 digital inputs 24V DC (1 input available in standard, integrated with PS32 or PS42 power supply module)
    Power consumption typical 15 VA, max. 20 VA
    Outputs 2 or 4: analogue 4 ÷ 20 mA (passive, isolated, resolution 14 bit); SPST relay 1A/250V; SSR passive (OC with PWM); mixed outputs (2 x REL / 2 x 4 ÷ 20 mA, 2 x REL / 2 x SSR passive, 2 x 4 ÷ 20 mA / 2 x SSR); sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)
  • MultiCon CMC-99
    The MultiCon CMC-99 is a powerful and versatile compact-multichannel-controller with a capability to record data, if the recording function is requested and activated. Thanks to that it...
    more
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Inputs 9 universal inputs max.; 48 analogue inputs (0/4-20 mA or 0/1-5V or 0/2-10V) max.; 48 digital inputs max.; 24 thermocouple inputs max.; 12 RTD inputs max.; 12 counter/ flowmeter/ ratemeter inputs max.; 1 digital input 24V DC (available in standard, integrated with PS3 or PS4 power supply module)
    Power consumption typical 15 VA; max. 20 VA
    Outputs 8 analog (4-20 mA) max.; 16 relay (1A/250V) max.; 4 relay 5A/250V max. or 48 SSR outputs, sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)
  • MultiCon CMC-141
    The Multicon CMC are powerful and versatile compact-multichannel-controllers with a capability to record data, if the recording function is requested and activated. MultiCon CMC‑141 is...
    more
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Inputs up to 15 universal inputs; 72 analogue inputs (0/4-20 mA or 0/1-5V or 0/2-10V) max.; 72 digital inputs max.; 36 thermocouple inputs max.; 18 RTD inputs max.; 12 counter/ flowmeter/ ratemeter inputs max.; 1 digital input 24V DC (available in standard, integrated with  PS3 or PS4 power supply module)
    Power consumption typical 25 VA; max. 35 VA
    Outputs 24 analog (4-20 mA) or 36 relay (1A/250V) / 72 SSR outputs or 18 relay 5A/250V max., sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)

SIMEX Sp. z o.o.

ul. Wielopole 11

80-556 Gdańsk

Poland

tel. (+48 58) 76-20-777

fax (+48 58) 76-20-770

inquiry@simex.pl