Website uses cookies in ways described in the cookie policy (read). While using this website without changing browser settings, you agree to use cookies, and know that some data will be stored on your browsing device. Mind that that you can always change these settings. Close
unia europejska

simex - pomiar i sterowanie

Temperature

 

Digital industrial meters constitute the largest family of automation equipment, ranging from the simplest meters that are designed only to display basic parameters such as working status or physical quantities (temperature, level, pressure etc.), to more complex control units having a number of relay outputs. Depending on the type of measured signal or required sensor, these appliances can be equipped with inputs suitable for Pt100 temperature sensors or thermocouples of the K, S, J, T, N, R, B and E types. There are a variety of designs: enclosures of different sizes and with displays in various sizes, even wall-mounted or board-mounted enclosures, enabling the free selection of appliances while maintaining complete functional compatibility The additional option of current output, installed in a number of appliances, enables the easy retransmission of the measured parameter to systems equipped with PLC controllers, or, for example, to other meters.

name
General descrption
parameters
  • SWE-73-T
    Simple digital panel indicator, equipped with measurement input Pt100, Pt500, Pt1000
    more
    Inputs temperature Pt100, Pt500, Pt1000, automatic recognition of 2, 3 and 4-conductor connection
    Power supply 110V AC ± 10%, 230V AC ± 10% or 24V DC (10V ÷ 30V DC), non separated from measurement input
    Power consumption for 110V AC and 230V AC: max. 1,5 VA; for 24V DC: max. 1 W
    Measurement range -100°C ÷ 600°C
  • SRT-73
    Temperature meter in a small case with inputs Pt100, Pt500, Pt1000 or thermocouple, with 1 or 2 relay / OC outputs. The version without relay outputs is also available.
    more
    Inputs thermoresistance: Pt100, Pt500, Pt1000; thermocouple: type K, S, J, T, N, R, B, E
    Outputs 0, 1 or 2 relays 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
  • STN-94
    Temperature meter with double display, with inputs Pt100, Pt500, Pt1000, with 1 relay / OC output.
    more
    Inputs thermoresistance: Pt100, Pt500, Pt1000
    Outputs 1 relay 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
  • SRT-94
    The SRT-94 temperature meter has one input: thermoresistance (Pt100/500/1000) or thermocouple (K, S, J, T, N, R, B, E). Measurement is linearised by the polynomial characteristics. The...
    more
    Inputs thermoresistance: Pt100, Pt500, Pt1000; thermocouple: type K, S, J, T, N, R, B, E
    Outputs 0, 2 or 4 relays 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
  • SRT-N118
    Temperature meter in tight, wall mounting case (IP 67), with a large, readable display, with inputs Pt100, Pt500, Pt1000 or thermocouple, with 2 relay / OC outputs (option) and 1...
    more
    Inputs thermoresistance: Pt100, Pt500, Pt1000; thermocouple: type K, S, J, T, N, R, B, E
    Outputs 0 or 2 relays 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC, all separated
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 5 VA; for 19V ÷ 50V DC power supply: max. 5 W
  • SRT-77
    Temperature meter with 2 displays, with inputs Pt100, Pt500, Pt1000 or thermocouple, with 1 or 2 relay / OC outputs. The version without relay outputs is also available.
    more
    Inputs thermoresistance: Pt100, Pt500, Pt1000; thermocouple: type K, S, J, T, N, R, B, E
    Outputs 0, 1 or 2 relays 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
  • SRT-L70
    Temperature meter on TS35 strip with inputs Pt100, Pt500, Pt1000, with 3 relay outputs.
    more
    Inputs thermoresistance: Pt100, Pt500, Pt1000
    Outputs 3 relays 8A/250V AC (2 NO, 1 NO-NC), transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
    Power supply 19V ÷ 90V DC; 16V ÷ 70V AC or 85 ÷ 260V AC/DC
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 70V AC power supply: max. 6,5 VA; for 19V ÷ 90V DC power supply: max. 6,5 W
  • SRT-147
    The SRT-147 meter is equipped with inputs Pt100, Pt500, Pt1000 or thermocouple. Additionally the SRT-147 allows user to select a conversion characteristic of several kinds: linear,...
    more
    Inputs thermoresistance: Pt100, Pt500, Pt1000; thermocouple: type K, S, J, T, N, R, B, E
    Outputs 0, 2 or 4 relays 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 11 VA; 19V ÷ 50V DC power supply: max. 8 W
  • SWT-99
    The SWT-99 indicator is intended for measuring and presentation of temperature values from 8 measuringchannels. Each channel can be individually designated (described) with any measuring...
    more
    Inputs 2, 4 or 8 inputs Pt100, Pt500, Pt1000, automatic recognition of 2 and 3-conductor connection
    Outputs 2 electronic relays, NO type (ER1, ER2) with max. load 24V AC (35V DC) / 200 mA, overload protection
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption typical 7 VA; max. 12 VA
  • MultiCon CMC-N16
    As a result of extending the range of functional applications of the MultiCon product line, the CMC-N16 wall mounted model has been designed. The new IP 65 enclosure allows using the...
    more
    Inputs 2 or 4 universal, isolated: 0/4 ÷ 20 mA (also totalizer mode); 0/1 ÷ 5V, 0/2 ÷ 10V; thermocouples: J, K, S, T, N, R, B, E (PN-EN), L (GOST); -10 ÷ 25 mV, -10 ÷ 100 mV, 0 ÷ 600 mV; RTD (2/3 wire): Pt100, Pt500, Pt1000 (PN-EN), Pt'50, Pt'100, Pt'500 (GOST), Ni100, Ni500, Ni1000 (PN-EN), Cu50, Cu100 (PN-83M-53852), Cu'50, Cu'100 (PN-83M-53852); resistance 0 ÷ 300 Ω, resistance 0 ÷ 3 kΩ; 2 universal pulse counter / ratemeter, (max. freq. 5 kHz); 5 digital inputs 24V DC (1 input available in standard, integrated with PS32 or PS42 power supply module)
    Outputs 2 or 4: analogue 4 ÷ 20 mA (passive, isolated, resolution 14 bit); SPST relay 1A/250V; SSR passive (OC with PWM); mixed outputs (2 x REL / 2 x 4 ÷ 20 mA, 2 x REL / 2 x SSR passive, 2 x 4 ÷ 20 mA / 2 x SSR); sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)
    Power supply 19-50V DC, 16-35V AC or 85-260V AC/DC
    Power consumption typical 15 VA, max. 20 VA
  • MultiCon CMC-99
    The MultiCon CMC-99 is a powerful and versatile compact-multichannel-controller with a capability to record data, if the recording function is requested and activated. Thanks to that it...
    more
    Inputs 9 universal inputs max.; 48 analogue inputs (0/4-20 mA or 0/1-5V or 0/2-10V) max.; 48 digital inputs max.; 24 thermocouple inputs max.; 12 RTD inputs max.; 12 counter/ flowmeter/ ratemeter inputs max.; 1 digital input 24V DC (available in standard, integrated with PS3 or PS4 power supply module)
    Outputs 8 analog (4-20 mA) max.; 16 relay (1A/250V) max.; 4 relay 5A/250V max. or 48 SSR outputs, sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption typical 15 VA; max. 20 VA
  • MultiCon CMC-141
    The Multicon CMC are powerful and versatile compact-multichannel-controllers with a capability to record data, if the recording function is requested and activated. MultiCon CMC‑141 is...
    more
    Inputs up to 15 universal inputs; 72 analogue inputs (0/4-20 mA or 0/1-5V or 0/2-10V) max.; 72 digital inputs max.; 36 thermocouple inputs max.; 18 RTD inputs max.; 12 counter/ flowmeter/ ratemeter inputs max.; 1 digital input 24V DC (available in standard, integrated with  PS3 or PS4 power supply module)
    Outputs 24 analog (4-20 mA) or 36 relay (1A/250V) / 72 SSR outputs or 18 relay 5A/250V max., sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption typical 25 VA; max. 35 VA

SIMEX Sp. z o.o.

ul. Wielopole 11

80-556 Gdańsk

Poland

tel. (+48 58) 76-20-777

fax (+48 58) 76-20-770

inquiry@simex.pl