Contact

SIMEX Sp. z o.o.

ul. Wielopole 7

80-556 Gdańsk

Poland

tel. (+48 58) 76-20-777

fax (+48 58) 76-20-770

export@simex.pl

inquiry@simex.pl

info@simex.pl

Data Acquistion

The TRS application-specific multi-point distributed recording system is designed to record quantities like temperature and humidity as part of vast control systems as found in the food industry, warehouses and maintenance storage areas, libraries etc. It is based on the RS-485 network using the ModBus protocol. Depending on needs, such a system may comprise several or several dozen or more measuring points. The specialized PC-based software enables the databasing of the recorded measurements, carrying out of analyses, print-outs etc.

view: details view general view
name
General descrption
parameters
  • TRS-01a
    The ambient temperature transducer is a basic device of the TRS System. It is designed particularly to measure temperature in rooms where food products are manufactured and stored. It... more
    Power supply typ. 10V DC (9V DC ÷ 12V DC)
    Input temp. sensor: semiconductor integrated circuit; measurement range -40°C ÷ +85°C; measurement error within th range -10°C ÷ +50°C: ±0,5°C
    Power consumption 4,2 mA; during Modbus transmission: do 60 mA
    Communication interface RS-485 / Modbus RTU
  • TRS-02a
    The temperature transducer is designed for multipoint measurement of temperature by means of a standard Pt100 sensor. In particular it is designed for use with bayonet sensors to be... more
    Power supply typ. 10V DC (9V DC ÷ 12V DC)
    Input temp. sensor: Pt 100; measurement range -50°C ÷ +550°C; measurement error ±0,2%
    Power consumption 12 mA; during Modbus transmission: do 65 mA
    Communication interface RS-485 / Modbus RTU
  • TRS-04a
    The temperature and humidity transducer is designed for multipoint temperature and humidity measurement systems. In particular it is used for measuring conditions in rooms where food... more
    Power supply typ. 10V DC (9V DC ÷ 12V DC)
    Input temp. sensor: semiconductor integrated circuit; measurement range -40°C ÷ +70°C; measurement error ±0,5°C; humidity sensor: 0 ÷ 100% RH, accuracy ±2% RH @25°C
    Power consumption during Modbus transmission: do 60 mA
    Communication interface RS-485 / Modbus RTU
  • TRS-09a
    TRS-09a is a supporting power supply for the TRS System which supplies stabilized direct voltage 11,5V. It can work in two modes: as a controlled supply (switched on with external... more
    Power supply 230V AC +10/-5%
    Power consumption max. 6 VA
    Output supply voltage 7 V ÷ 12 V, max. 2 mA; supply output voltage 11,5 V ±5%
    Operating temperature 0°C ÷ +50°C
  • TRS-10a
    The TRS-10a wall mounted indicator is designed to display digital values and short, 4-letter messages. This superior system makes the display flicker when a displayed value is not... more
    Power supply typ. 10V DC (9V DC ÷ 12V DC)
    Display 4 digits 9 mm high, increased brightness
    Power consumption do 30 mA; during Modbus transmission: do 80 mA
    Communication interface RS-485 / Modbus RTU
  • TRS-11a
    The TRS-11a ambient temperature transducer with a display is designed for multipoint temperature measurement within the range of -40°C up to +85°C. It is particularly designed to... more
    Power supply typ. 10V DC (9V DC ÷ 12V DC)
    Input temp. sensor: semiconductor integrated circuit; measurement range -40°C ÷ +85°C; measurement error within th range -10°C ÷ +50°C: ±0,5°C
    Display 4 digits 9 mm high, increased brightness
    Power consumption do 30 mA; during Modbus transmission: do 80 mA
  • TRS-B1a
    The TRS-B1a sound signal device is designed to signal events with a sound or light. It is controlled by means of RS-485 link, which allows for activating of the sound signal (a buzzer... more
    Power supply typ. 10V DC (9V DC ÷ 12V DC)
    Power consumption 9.5 mA in standby; 70 mA while signalling; up to 60 mA when signalling switched off
    Communication interface RS-485 / Modbus RTU
    Operating temperature -40°C ÷ +85°C
  • SRS-2/4-Z16-B1a
    Recorder SRS-2/4-Z16-B1a is a two-processor device equipped with a real time clock powered with a lithum battery and flash nonvolatile memory (1 MB) to record approx. 40 000... more
    Power supply typ. 12V DC
    Galvanic separation output of the supply and signals of RS-485 link from RS-232 link
    Output supply voltage 10,5 V ±5%
    Communication interface RS-232
  • SOC-8
    The SOC-8 binary outputs module is used to control the low-power output devices via the RS-485 connection. It finds application in distributed control and visualization systems. It can... more
    Power supply typ. 24V DC (16V DC ÷ 30V DC)
    Power consumption typ. 20 mA
    Galvanic separation all 8 outputs are galvanically isolated from module supply and RS-485 interface
    Max output current 0.5A / single output, max. 2 active outputs; 0.2A / single output, all outputs active
  • Fastrack Supreme FS20
    Fastrack FS20 modem has proven itself for stable, reliable performance on wireless networks worldwide. Dual Band GSM/GPRS modem (EGSM900/1800 MHz) designed for data, fax, SMS and voice... more
    Power supply 5,5V - 32V
    Power consumption 18 mA in idle mode; 110 mA in communication GSM 900@13,2V; 80 mA in communication GSM 1800@13,2V
    Communication interface RS-232 i Audio through mini sub-D 15-pin connector supporting serial link autoshutdown controlled by software AT (GSM 07.07 i 07.05)
    Case dimensions 73 x 54 x 25 mm