Website uses cookies in ways described in the cookie policy (read). While using this website without changing browser settings, you agree to use cookies, and know that some data will be stored on your browsing device. Mind that that you can always change these settings. Close
unia europejska

simex - pomiar i sterowanie

Stationary

The process of controlling industrial processes is not based solely on control systems, but also on comprehensive recording and controlling of the course of such processes, as required for any subsequent verification of their correctness. However, it is seldom necessary to install a complicated recorder with expanded mathematical options/functions and vast memories. The most common requirement is for a multi-channel (e.g. 8-channel) recording of the typical signals used by automatic equipment (0/4-20 mA current signals) during periods usually not exceeding a month.

name
General descrption
parameters
  • MultiCon CMC-N16
    As a result of extending the range of functional applications of the MultiCon product line, the CMC-N16 wall mounted model has been designed. The new IP 65 enclosure allows using the...
    more
    Inputs 2 or 4 universal, isolated: 0/4 ÷ 20 mA (also totalizer mode); 0/1 ÷ 5V, 0/2 ÷ 10V; thermocouples: J, K, S, T, N, R, B, E (PN-EN), L (GOST); -10 ÷ 25 mV, -10 ÷ 100 mV, 0 ÷ 600 mV; RTD (2/3 wire): Pt100, Pt500, Pt1000 (PN-EN), Pt'50, Pt'100, Pt'500 (GOST), Ni100, Ni500, Ni1000 (PN-EN), Cu50, Cu100 (PN-83M-53852), Cu'50, Cu'100 (PN-83M-53852); resistance 0 ÷ 300 Ω, resistance 0 ÷ 3 kΩ; 2 universal pulse counter / ratemeter, (max. freq. 5 kHz); 5 digital inputs 24V DC (1 input available in standard, integrated with PS32 or PS42 power supply module)
    Power consumption typical 15 VA, max. 20 VA
    Outputs 2 or 4: analogue 4 ÷ 20 mA (passive, isolated, resolution 14 bit); SPST relay 1A/250V; SSR passive (OC with PWM); mixed outputs (2 x REL / 2 x 4 ÷ 20 mA, 2 x REL / 2 x SSR passive, 2 x 4 ÷ 20 mA / 2 x SSR); sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)
    Case material ABS (case), polycarbonate (front panel)
  • MultiCon CMC-99
    The MultiCon CMC-99 is a powerful and versatile compact-multichannel-controller with a capability to record data, if the recording function is requested and activated. Thanks to that it...
    more
    Inputs 9 universal inputs max.; 48 analogue inputs (0/4-20 mA or 0/1-5V or 0/2-10V) max.; 48 digital inputs max.; 24 thermocouple inputs max.; 12 RTD inputs max.; 12 counter/ flowmeter/ ratemeter inputs max.; 1 digital input 24V DC (available in standard, integrated with PS3 or PS4 power supply module)
    Power consumption typical 15 VA; max. 20 VA
    Outputs 8 analog (4-20 mA) max.; 16 relay (1A/250V) max.; 4 relay 5A/250V max. or 48 SSR outputs, sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)
    Case material NORYL - GFN2S E1
  • MultiCon CMC-141
    The Multicon CMC are powerful and versatile compact-multichannel-controllers with a capability to record data, if the recording function is requested and activated. MultiCon CMC‑141 is...
    more
    Inputs up to 15 universal inputs; 72 analogue inputs (0/4-20 mA or 0/1-5V or 0/2-10V) max.; 72 digital inputs max.; 36 thermocouple inputs max.; 18 RTD inputs max.; 12 counter/ flowmeter/ ratemeter inputs max.; 1 digital input 24V DC (available in standard, integrated with  PS3 or PS4 power supply module)
    Power consumption typical 25 VA; max. 35 VA
    Outputs 24 analog (4-20 mA) or 36 relay (1A/250V) / 72 SSR outputs or 18 relay 5A/250V max., sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)
    Case material NORYL - GFN2S E1
  • MultiLog SRD-99X
    The new MultiLog SRD-99X device is designed to record and display current values as well as to present technological parameters in the form of graphs. The device is equipped with up to...
    more
    Inputs 1, 4 or 8 x universal inputs: U/I (0/4-20 mA, 0/1-5 V, 0/2-10V or mixed) or temperature (Pt100/Pt500/Pt1000, TC K, S, J, T, N, R, B, E or mixed); 1 digital input 24V DC, optocoupled
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
    Power consumption typical 7 VA; max. 12 VA
    Outputs 2 electronic relays (ER1, ER2) with max. load 24V AC (35V DC) / 200 mA; sensors supply (only current/voltage version): 24 V DC ± 5%, max. 200 mA, not separated from measuring inputs
  • MultiLog SRD-N16
    The MultiLog SRD-N16 device is designed to record and display current values as well as to present technological parameters in the form of charts. The instrument can be equipped with up...
    more
    Inputs 1, 4 or 8: current: 0-20 mA or 4-20 mA; voltage: 0-5 V, 1-5V, 0-10V or 2-10V; RTD: Pt100, Pt500, Pt1000; thermocouple: K, S, J, T, N, R, B, E type
    Outputs 2 relays (R1, R2), Imax=1A, Umax=30VDC/250VAC (cosø=1)
    Case material ABS (case), polycarbonate (front panel)
    Power supply 19V ÷ 50V DC; 16V ÷ 35V AC lub 85 ÷ 260V AC/DC

SIMEX Sp. z o.o.

ul. Wielopole 11

80-556 Gdańsk

Poland

tel. (+48 58) 76-20-777

fax (+48 58) 76-20-770