Data acquisition systems

Remote data acquisition systems based on the ModBus RTU protocols enable the creation of a multi-point control system for various parameters of the technological process. This type of system, thanks to the significant reduction of the necessary wiring (usually to a single four-conductor line), is becoming increasingly popular in new or modernised control and supervision systems. The basic element of each remote acquisition system is a measuring module. Each module differs in its design of input circuits, as they are used to measure different electrical quantities. Among the vast range of measuring modules, the most commonly used are those for the measuring of temperature, current, or voltage, as well as modules for binary inputs and meter modules. The measured data can be transmitted up to 1,000m, thanks to the use of the RS-485 connection.

view: details view general view
name
General descrption
parameters
  • SIN-8
    Module type SIN-8 allows to monitor 8 binary voltage inputs via the RS-485 connection. It finds application in distributed control and visualization systems. Standard Modbus protocol... more
    Power supply typ. 24V DC (16V DC ÷ 30V DC)
    Current consumption typ. 20 mA
    Input 8 binary
    Input levels LOW state: 0V (0 ÷ 3V); HIGH state: 24V (15 ÷ 24V); min. duration of LOW and HIGH state: 50 µs
  • SLI-8
    Multi counters module SLI-8 allows to counting of pulses delivered to 8 isolated binary inputs independently. All counters are 24 bit long and can be read and cleared by user at any... more
    Power supply typ. 24V DC (16V DC ÷ 30V DC)
    Input 8 binary; counters capacity: 4 294 967 295 (32 bits)
    Current consumption typ. 20 mA
    Input levels LOW state: 0V; HIGH state: 24V (min. 8V)
  • SIAi-8
    Module SIAi-8 allows to measure analog values from 8 current (or voltage) inputs via the RS-485 connection, with speed rate about 10 Hz (every channel). Measurement results can be... more
    Power supply typ. 24V DC (16V DC ÷ 30V DC)
    Input SIAi-8P: 8 x current 0-20 mA; 4-20 mA; SIAi-8N: 8 x voltage 0-10 V; 2-10 V; 0-5 V; 1-5 V
    Current consumption typ. 20 mA
    Galvanic separation all 8 inputs are galvanically isolated from module supply and RS-485 interfac
  • SOC-8
    The SOC-8 binary outputs module is used to control the low-power output devices via the RS-485 connection. It finds application in distributed control and visualization systems. It can... more
    Power supply typ. 24V DC (16V DC ÷ 30V DC)
    Current consumption typ. 20 mA
    Galvanic separation all 8 outputs are galvanically isolated from module supply and RS-485 interface
    Output 8 binary; max output current: 0.5A / single output, max. 2 active outputs; 0.2A / single output, all outputs active