STI-N118

Other products in this category: previous product next product

STI-N118 ratemeters in tight, wall mounted case (IP 65), are designed to control rotational speed (from 1,5 to 50000 rev/min) or its inversion (revolution period). Available parameters of divider and multiplier enable flexible scaling of measure and transformation into linear speed. On top of that, they enable operation in the frequency and period meter mode, what allows to show e.g. material linear speed, baking time, drying time, revolution period.

Parameters

Power supply 230 V AC ± 10%; 110 V AC ± 10%; 24 V DC (non separated from measurement input)
Input pulse, fully isolated, with debouncing filter and pulse width control, max. input frequency 50.0 kHz
Display LED, red (green on request), 6 x 13 mm high, with 8-step adjustment of brighness
Data memory non-volatile memory, EEPROM type
Displayed values range 0 ÷ 999999 + decimal point
Power consumption for 110V AC and 230V AC: max. 2,6 VA; for 24V DC: max. 4,5 W
Output 0 or 2 relay 1A/250V AC (cos fi=1) or OC 30mA/30VDC/100mW; power supply output: 24V DC + 5% -10% / max 100 mA
Communication interface RS-485 / Modbus RTU (not galvanically isolated)
Accuracy frequency measurement: ± 0.02% (full temperature range)
Transmission parameters 1200 ÷ 115200 bit/s, 8N1 and 8N2
Operating temperature 0°C ÷ +50°C (standard), -20°C ÷ +50°C (option)
Storage temperature -10°C ÷ +70°C; -20°C do +70°C (depending on version)
Protection class IP 65
Case wall-mounted
Pulse waiting time settable from 0,1 to 39,9 seconds
Rotational speed accuracy selected in the range 0 ÷ 0,00000
Case dimensions without glands: 110 x 80 x 67 mm; with glands: 110 x 105 x 67 mm
Rotational speed unit revolutions per second (rps), per minute (rpm), per hour (rph)